- Input Voltage Range
- Primary supply: 115 V AC, 400 Hz (100 to 125 V RMS)
- Redundant supply: 28 V DC ( min: 16 V, Max: 32 V)
- Reverse Polarity Protection (DC Inputs) : Yes
- Efficiency : Min 85% @ Full Load
- Output Voltages: 3 V DC, 5 V DC, 12 V DC,
- Input Under Voltage Protection: Below 108 V AC, switch over to 28 V DC supply. If DC voltage is below 16 V or above 32 V, Output switch off
- Input Over Voltage Protection : Primary supply is above 118 V AC, 400 Hz, switch over to 28 V DC supply If DC voltage is also below 16V or above 32 V, switch off
- 3V DC (AUX): 5A
- 5V DC: 20A
- 12V DC: 25A
- 3V DC < 50mV
- 5V DC < 50 mV
- 12V DC < 200 mV
- 3V DC < 20mV
- 5V DC < 20 mV
- 12V DC < 100 mV
- 3V DC < 50mV
- 5V DC < 50 mV
- 12V DC < 200 mV
- Hold-up Time: 50 ms when operating at full load
Output Currents:
Ripple:
Line Regulation:
Load Regulation: